EMERGENCY LIGHTING INSTALLATION LOCATIONS


It is important that emergency lighting luminaires are installed in such a manner that they will provide adequate lighting when the normal lighting system malfunctions. The locations that need to be considered when designing an emergency lighting system are listed below. These locations must be clearly identified when designing an emergency lighting system.

Open Areas

Open areas generally must be equipped with anti-panic lighting. For the most part, such areas have a floor area measuring more than 60 square meters or they have been identified as needing such lighting as the result of fire risk assessments

Emergency exits and escape routes

Emergency exits and escape routes must be clearly marked and illuminated so they indicate a clear route to a place of safety. When an emergency exit is not immediately visible, an illuminated sign or series of signs pointing in the right direction must be installed. Changes in direction along routes to an emergency exit must be illuminated. An escape lighting luminaire (compliant with IEC/EN 60598-2-22) must be installed next to every exit and other such locations to highlight potential hazards or point the way to safety equipment.

Emergency luminaires must be installed next to fire safety equipment and near the following points:

 • All exits that will be used in emergencies

• The entire length of staircases

• Points where the floor level changes

• Above mandatory emergency exits and safety signs

• Points where changes of direction occur along escape routes

• At the intersections of hallways

• Above and outside every final exit

• Above first aid cabinets

• Above fire extinguishing equipment

• Above fire alarm buttons

Share



Other Posts

WHAT IS THE EMERGENCY LIGHTING?

Emergency lighting is a type of secondary lighting that activates immediately, independent of a generator system, when the usual lighting system is disabled due to emergencies involving events such as earthquakes, fires, terror attacks, sabotage, or power outages. Emergency lighting systems allow for the safe evacuation of people from a building.

REGULAR TESTING, MAINTENANCE, AND REGISTRATION 

Buildings that will be fitted with emergency lighting must have a project plan that is in accordance with the Interior Electrical Wiring Project Regulation, and it must be submitted to the building authorities. Correct planning saves lives. The project plan must include all devices to be used, and it must be signed by an expert to verify that it conforms to all relevant standards and regulations.